Tighthouse Passive House
As the first official Certified Passive House in New York City, the Tighthouse embodies the opportunity for old masonry buildings to achieve exceptional energy performance.
-
Walls/Roof/Foundation
EIFS stucco
Masonry
Steel beam
Steel studsWindows/Doors
U Value 0.16
Insulation
EIFS with EPS foam, closed cell spray foam and mineral wool
R10 Slab
R20/R30 Foundation
R30 Above Grade Walls
R60 Roof -
Heating/Cooling
Ducted air source heat pump (9HSPF, 15 SEER)
Ventilation
HRV (95% sensible, 0.42 W/cfm)
Hot Water
Solar hot water
-
Goals. As part of the home's full renovation and addition, the homeowner sought the consulting and mechanical design assistance of ZED to target exceptional energy performance and vastly improve the comfort of the house.
Solution. ZED developed a building enclosure for both the renovated portion home and the new addition that minimizes air leakage, thermal bridging, and heat loss. The latest in high efficiency all electric systems were installed, and paired with a solar electric system to help offset consumption.
Enclosure. The super-insulated building enclosure includes walls and roof both utilizing wood frame construction, filled with dense packed cellulose, plus 2" for the walls and 4" for the roof of polyiso exterior to the sheathing. A taped building wrap over the sheathing and under the polyiso acts as the primary air barrier. The windows are all triple pane throughout the home.
Systems. A ground source heat pump provides radiant floor heating and ducted cooling for the house, while an energy recovery ventilator offers constant balanced fresh air with heat recovery. A 10.1 kW PV system helps off-set energy consumption. A Stiebel Eltron heat pump hot water heater creates domestic hot water for the house. Appliances are energy efficient, including an induction cooktop, and lighting is LED.
Result. The house uses 85% less energy than a comparable house built to minimum code requirements. Additionally, it offsets nearly 100% of its energy consumption on-site through photovoltaic panels, essentially achieving net zero energy.
Location: Brooklyn, New York
Services:
Energy Consulting
Performance:
EUI: 8.2 kBtu/sf/yr
Air Leakage 0.38ACH50
Heat Demand 4.42 kBTU/(ft2yr)
Air Tightness 0.38 ACH50 (first test)
Primary Energy 35.00 kBTU/(ft2yr)
Cooling Demand 1.42 kBTU/(ft2yr)
Heat Load 6.08 kBTU/(ft2yr)
Cooling Load 7.74 kBTU/(ft2yr)
Certification:
Certified Passive House
Project Team:
Architecture: Fete Nature Architecture
Passive House Consultant & Mechanical Designer: ZED